Blade ICE G8124 Manuale Utente

Pagina di 388
BLADEOS 6.5.2 Application Guide
372  

  Chapter 27: Remote Monitoring
BMD00220, October 2010
Configuring RMON History
Perform the following steps to configure RMON History on a port. 
1.
Enable RMON on a port.   
2.
Configure the RMON History parameters for a port.   
where <x> is the number of the port to monitor. For example, the full OID for port 1 would be:
1.3.6.1.2.1.2.2.1.1.1
3.
View RMON history for the port.   
RS G8124(config)# interface port 1
RS G8124(config-if)# rmon
RS G8124(config-if)# exit
RS G8124(config)# rmon history 1 interface-oid 1.3.6.1.2.1.2.2.1.1.
<x>
RS G8124(config)# rmon history 1 requested-buckets 30
RS G8124(config)# rmon history 1 polling-interval 120
RS G8124(config)# rmon history 1 owner "rmon port 1 history"
RS G8124(config)# show rmon history
RMON History group configuration:
Index
IFOID
Interval
Rbnum
Gbnum
-----
-----------------------
--------
-----
-----
1
1.3.6.1.2.1.2.2.1.1.1
120
30
30
Index
Owner
-----
----------------------------------------------
1
rmon port 1 history