 5200/5300 Adjustments (
not
 for 5260, 5280)
High Voltage - 40
Replacement Note:
  Perform 
the high voltage adjustment 
whenever you replace the 
CRT or the deflection board.
Note:
  Perform the high 
voltage adjustment after the 
monitor has been on for at 
least 10 minutes.
1 Run Display Service 
Utility to display the 
Crosshatch test pattern.
2 Locate diode D713 (Rev. 
A) or D703 (Rev. B) on 
the analog board. 
R751
R749
D713
R751
R749
D713
Analog
Board
Black Lead
29.5
VDC
Voltmeter 
Reads
Chassis
Ground
Red Lead
Run 
Display Service 
Utility
Crosshatch 1
Test Pattern
Rev  A