Chapter 1: Switch Administration  

  29
Using the Switch Data Ports
You also can configure in-band management through any of the switch data ports. To allow in-band 
management, use the following procedure: 
1.
Log on to the switch. 
2.
Enter IP interface mode.  
Note – 
Interface 125 through 128 are reserved for out-of-band management interfaces (see 
).
3.
Configure the management IP interface/mask.

Using IPv4:

Using IPv6:
4.
Configure the VLAN, and enable the interface. 
5.
Configure the default gateway.

If using IPv4:

If using IPv6:  
RS G8124> enable
RS G8124# configure terminal
RS G8124(config)# interface ip
<IP interface number>
RS G8124(config-ip-if)# ip address
<management interface IPv4 address>
RS G8124(config-ip-if)# ip netmask
<IPv4 subnet mask>
RS G8124(config-ip-if)# ipv6 address
<management interface IPv6 address>
RS G8124(config-ip-if)# ipv6 prefixlen
<IPv6 prefix length>
RS G8124(config-ip-if)# vlan 1
RS G8124(config-ip-if)# enable
RS G8124(config-ip-if)# exit
RS G8124(config)# ip gateway
<gateway number>
address
<IPv4 address>
RS G8124(config)# ip gateway
<gateway number>
enable
RS G8124(config)# ip gateway6
<gateway number>
address
<IPv6 address>
RS G8124(config)# ip gateway6
<gateway number>