Emerson ATCA-S201 Manuale Utente
![Emerson](https://files.manualsbrain.com/attachments/1ef3aaad462e024fde6cecf537a4c6c781334d44/common/fit/150/50/6dab323528eefa0342baa74a10c15551c3b956250cf9d62f2117dcdf42a7/brand_logo.jpeg)
RTM-ATCA-SXXX Overview
6806800H62B
ATCA‐S201 Installation and Use Guide
82
Target iqn.1995-07.com.emerson:ATCA-S201.Target0
Alias
NoAlias
MaxConnections
1
InitialR2T
No
ImmediateData
Yes
MaxRecvDataSegmentLength
262144
MaxXmitDataSegmentLength
262144
MaxBurstLength
262144
FirstBurstLength
65536
DefaultTime2Wait
2
DefaultTime2Retain
20
MaxOutstandingR2T
8
DataPDUInOrder
1
DataSequenceInOrder
1
ErrorRecoveryLevel
0
HeaderDigest
None
DataDigest
None
Wthreads
8
IET tid
1
IncomingUser[0]
OutgoingUser[0]
0 LUNs Served By This Target
LUN
Path
Type
Remove
Add a new LUN Share to This Target
LUN
Path
Type
Action
blockio
Add Lun
0
ˇ
lva0
ˇ
Delete This iSCSI Target
1 LUNs Served By This Target
LUN
Path
Type
Remove
0
/export/iSCSI/lva0
blockio
Remove
Add a new LUN Share to This Target
LUN
Path
Type
Action
blockio
No paths available
1
ˇ
ˇ
Fol
low these instructions to create an iSCSI LUN
Step 2.
Use the LUN Drop down menu, to specify the LUN assignment for the
resource.
Step 3.
Use the Path Drop down menu, to specify the logical device that will map to
this LUN.
this LUN.
Step 4.
Click the ‘Add LUN button. Repeat to add additional LUNs.