Emerson ATCA-7150 Manuale Utente

Pagina di 122
   
Hardware Installation of ATCA-7150
ATCA-7150 and RTM-ATCA-7150 Getting Started (6806800G42B)
81
z
Preparing spare parts and tools
Prepare the component to be installed or replaced.
When you hold or transport the component, use the special antistatic package. Also, 
you need to tidy, record, and repair the component during routine maintenance.
Prepare the cross screwdriver, screws, plastic supports, cooling gel, and ESD-
preventive wrist strap.
The supplier provides a list of tools and negotiates with to decide the tool provider.
z
Confirming installation or changing position
Confirm the positions of the cabinet, the shelf, and the slot where the ATCA-7150 is 
installed. Then, stick a label on the face plate of the ATCA-7150 to avoid wrong operation.
z
Others
If a serious problem occurs and cannot be solved when you install or replace the 
component, contact Emerson Network Power for technical support. For details on contact 
methods, see 
.
3.6.4
DIMM
When you install or replace the DIMM, pay attention to the following points: 
z
The ATCA-7150 provides four DIMM interfaces and supports the DIMM with a capacity of 
512 MB, 1 GB, 2 GB or 4 GB.
z
The DIMMs must have the same size, frequency, type, and technology, physical design and 
manufacturer.
z
DIMMs must be of single or dual rank type. Quad rank types are not supported.
z
If the DIMMs are not fully configured, you need to install the required DIMMs in the related 
interfaces.
If one DIMM is configured, install it in DIMM slot 0.
If two DIMMs are configured, install them in DIMM slots 0 and 1.
Configuring three DIMMs is not supported.