Extron electronic PS 124 Manuale Utente

Pagina di 24
PS 124  12 VDC, 4 Amp Power Supply • Installation Manual
 
13
5
.
Assemble the U-bolt and the following parts in order:
a
.  Pass the legs of the U-bolt through the slotted holes on
the mount plate flange.
b
.  Place the legs around the ceiling pole.
c
.  Pass the legs through the holes in the contoured base.
N
 
The pole fits snugly into the depression in the center of 
the contoured base.
d
.  Pass the legs through the holes in the L-shaped bracket.
N
 
The bracket slots can accommodate 1.0" to 2.0" diameter 
poles.  The supplied square U‑bolt fits 1.5" to 2.0" 
diameter poles.  If a smaller diameter pole is used, obtain 
the proper size square U‑bolt locally.  
U-bolt
Slotted Hole
in PMK Tray
L-shaped
Bracket
L-shaped
Bracket Screws
Contoured
Base
Ceiling
Pole
Mount Plate
Flange
Figure 12 — Projector mounting the PS 124
6
.
Align the two slotted holes in the bottom of the L-shaped
bracket with the two slotted holes in the base of the
tray. Secure the L-bracket to the base by inserting two
6-32 x 5/16" screws (provided) through the aligned slots.
7
.
Move the PMK 350 to the desired location on the ceiling
pole, as close to the ceiling as desired.
8
.
Secure the L-shaped bracket to the U-bolt using the
included hex nuts, washers, and lock washers. Tighten the
hex nuts securely.
C
 
A socket wrench is recommended to tighten the 
hex nuts so the PMK 350 does not slide down the 
ceiling pole.  
9
.
Secure the front panel to the mounting tray with four of
the included #6 screws.
10.
  If desired, apply one of the cover sheets to the underside of 
the mounting tray (figure 11).