Panasonic A4P Series Manuale Utente

Pagina di 232
62
Parameter Setup
Standard default : < >
Servo
PrNo.
Setup
range
Unit
Title
Function/Content
21
0 to 7
<1>
Real time auto 
tuning set up
You can set up the action mode of the real-time auto-gain tuning.
With higher setup such as 3 or 6, the driver respond quickly to the change 
of the inertia during operation, however it might cause an unstable 
operation. Use 1 or 4 for normal operation.For the vertical axis application, 
use with the setup of 4 to 6.
When vibration occurs at gain switching, set up this to "7".
Setup value
0
<1>
2
3
4
5
6
7
Real-time
auto-gain tuning
   Invalid
Normal mode
  
Vertical axis mode
No gain switching
Varying degree of 
load inertia in motion
Little change
Gradual change
Rapid change
Little change
Gradual change
Rapid change
Little change
24
0 to 2
<0>
Vibration 
suppression filter 
switching selection
You can select the switching method when you use the vibration 
suppression filter.
25
0 to 7
<0>
Normal auto tuning 
motion setup
You can set up the action pattern at the normal mode auto-gain tuning. 
e.g.) When the setup is 0, the motor turns 2 revolutions to CCW and 2 
revolutions to CW.
Setup value
<0>
1
2
3
4
5
6
7
Number of revolution
2 [revolution]
1 [revolution]
Rotational direction
CCW     CW
CW     CCW
CCW     CCW
CW     CW
CCW     CW
CW     CCW
CCW     CCW
CW     CW
23
0 to 2
<1>
Adaptive filter 
mode
You can set up the action of the adaptive filter.
22
0 to 15
A to C-frame:
<4>
D to F-frame:
<1>
Machine stiffness 
at auto tuning
You can set up the machine stiffness in 16 steps while the real-time auto-
gain tuning is valid.
<Caution>
When you change the setup value rapidly, the gain changes rapidly as 
well, and this may give impact to the machine.  Increase the setup 
gradually watching the movement of the machine.
low    machine stiffness    high
low          servo gain         high
low           response          high
SV.Pr22        0, 1- - - - - - - - - - - - 14, 15  
Setup value
0
<1>
2
Content
Invalid
Valid
Hold (holds the adaptive filter frequency when this setup is changed to 2.)
Setup value
<0>, 1
2
Content
No switching (both of 1st and 2nd are valid.)
You can switch with the position command direction.
   CCW : 1st damping filter selection (SV.Pr2B, 2C).
   CW    : 2nd damping filter selection (SV.Pr2D, 2E).