Xantrex Technology XDL 35-5TP Manuale Utente

Pagina di 180
  
Specification 
General specifications apply for the temperature range 5°C to 40°C.  Accuracy specifications 
apply for the temperature range 18°C to 28°C after 1 hour warm-up with no load and calibration at 
23°C.  Typical specifications are determined by design and are not guaranteed.   
MAIN OUTPUTS 
Voltage/Current 
Ranges: 
The 3 operating ranges are:   0V to 35V/0·001A to 3A 
    0V 
to 
35V/0·1mA 
to 
500mA 
    0V 
to 
15V/0·001A 
to 
5A 
Voltage Setting: 
Resolution 1mV  
Accuracy ± (0·03% + 5mV) 
Current Setting: 
Resolution 1mA; 0·1mA on 500mA range 
Accuracy ± (0·2% + 5mA); ± (0·2% + 0·5mA) on 500mA range. 
Output Mode: 
Constant voltage or constant current with automatic cross-over. 
CI indicator lit in constant current mode. 
Output Switch: 
Electronic, non isolating. Switch illuminated when Output on.  
Preset voltage and current limit displayed when Output off. 
Output Terminals: 
4mm terminals on 19mm (0·75”) spacing for Output; screwless terminals 
for Sense. Duplicate rear panel Output and Sense screw terminals on 
remote control model (XDL 35-5TP). 
Transient Response: 
<50
µs to within 15mV of set level for a change in load current from full 
load to half load or vice versa. 
Voltage Programming 
Speed: 
Maximum time required for output to settle within 1% of its total 
excursion (for resistive load).  Excludes command processing time. 
 
 
Up  
15V 5A 
Up  
35V 3A 
Up  
35V 500mA 
  Full Load 
      6ms 
    20ms 
   200ms 
No Load    
     6ms 
     7ms 
   40ms 
 
Down   15V 5A 
Down   35V 3A 
Down   35V 500mA 
   6ms 
   25ms 
   120ms 
   250ms 
   600ms 
   600ms 
Ripple and Noise  
(20MHz bandwidth): 
Normal mode voltage:  <0·35mVrms and 2mVp-p 
Normal mode current:  <0·2mArms;  <20
µArms on 500mA range. 
Load Regulation: 
For any load change, measured at the output terminals, using  
remote sense. 
Voltage <0·01% + 2mV.  
Current <0·01% + 250µA; <0.01% +50µA on 500mA range. 
Add typically 2·5mV for a 0·5V drop in the positive output lead.  
Specification applies for sense lead resistance <0·5
Ω. 
Line Regulation: 
Voltage <0·01% + 2mV for 10% line change. 
Current <0·01% + 250µA; <0.01%+ 50µA on 500mA range. 
Temperature 
Coefficient: 
Voltage:  
typically <(50ppm + 0·5mV)/°C 
Current: 
typically <(100ppm + 1mA)/°C;  
 
 
               (100ppm + 0·1mA)/°C on 500mA range. 
Output Protection: 
Output will withstand forward voltages of up to 20V above rated output 
voltage. Reverse protection by diode clamp for currents up to 3A. 
Over-voltage 
Protection: 
  (OVP) 
Range 1V to 40V 
Resolution 0·1V; accuracy ± (2% + 0·5V) 
Response time typically 100
µs 
 6