Xantrex Technology C35 Manuale Utente

Pagina di 114
Operation
56
975-0004-01-02 Rev D
Charge Control or Diversion Control Indications 
(Green)
The flashing rate of the LED indicates the controller’s stage 
of operation and approximate battery voltage. 
One to four flashes indicates the controller is in the Bulk 
stage. As the flashing rate increases, the batteries are 
progressively closer to the Bulk voltage. Table 3-1 
indicates the approximate level the battery is below the 
Bulk setting.
Five flashes indicates the controller has reached Bulk 
voltage and is in the Absorption stage.
Solid green means the controller is in the Float stage and 
is regulated at the Float voltage.
Table 3-1 Battery Voltage LED Indicators
Green LED
(Charge/Diversion Mode)
LED 
Status
Red LED 
(Load Control Mode)
Battery at FLOAT Setting
Always 
ON
Battery at LVD Setting 
(for 6 minutes = LVD)
Battery at BULK Setting
5 blinks
> 0.15 
above 
LVD
>0.03 
above 
LVD
>0.45 
above 
LVD
BULK Setting Minus (–)
LVD Setting Plus (+)
0.25 Vdc
0.50 Vdc
1.00 Vdc
4 blinks
0.15 Vdc
0.30 Vdc
0.45 Vdc
0.50 Vdc
1.00 Vdc
2.00 Vdc
3 blinks
0.30 Vdc
0.60 Vdc
0.90 Vdc
0.75 Vdc
1.50 Vdc
3.00 Vdc
2 blinks
0.45 Vdc
0.90 Vdc
1.35 Vdc
> 0.75 
below Bulk
> 1.50 
below Bulk
> 3.00 
below Bulk
1 blink
> 0.45 
below Bulk
> 0.90 
below Bulk
> 1.375 
below Bulk
12 volts
24 volts
48 volts
DC 
Voltage
12 volts
24 volts
48 volts