Operating Modes
975-0004-01-02 Rev D
3
Indoor-type, powder-coated enclosure, for wall 
mounting.
Conformal-coated circuit boards, plated terminals, 
powder-coated metal components, and stainless steel 
fasteners improves tolerance to hostile environments.
Meets National Electrical Code (NEC) and other 
international controller specifications.
The C35, C40 and C60 models are UL listed to the 
U.S. UL Standard 1741 (1st edition), and Canada 
(CSA-C22.2 No. 107.1-95).
2-year limited warranty.
Operating Modes
The DC controller is a critical component in any solar, wind 
or hydro power generation system and protects the batteries 
from over-discharge and over-charge conditions. The 
C-Series
 has two operating modes (Charge Control mode and 
Load Control mode determined by the Operating mode 
jumper (See Figure 2-5). These two different operating 
modes allow the C-Series to be installed and function as three 
different DC controllers.
Charge Control Mode
• PV Charge Controller - controls charging in PV 
installations.
• Diversion Controller – used in PV, wind, or hydro 
installations to divert any excess energy to a diversion 
load and in the case of a wind or hydro generator, helps 
to prevent over-spin damage.
Load Control Mode
• Load Controller - prevents damage to the battery from 
over-discharge during periods of poor charging or 
excessive loads.