Ultra Products ULT31502 Dépliant

Pagina di 1
1-800-830-0051
www.ultraproducts.com
Automatic Voltage Regulation (AVR)
Protect your computer from electrical damage caused 
by dangerous "spikes and sags".
$125,000 Limited Warranty
Includes
UPS Monitoring
Software
Uninterrupted 
Power Supply (UPS)
The Ultimate Power Protection!
If you're looking for the most complete, technologically advanced power 
protection unit for the money, the Ultra UPS line is exactly what you need.  An 
Ultra UPS is an absolute must for anyone running a small server, workstation or a 
powerful PC.  You simply cannot afford to cut corners when it comes to 
safeguarding your valuable equipment, and these UPS's deliver the 
comprehensive protection for computer, peripherals and data files at a 
remarkably low price.  
 
Features
    - Line Interactive Design    
    - AVR (Automatic Voltage Regulation)
    - Fully Digitized Microprocessor Controlled
    - Protects up to 4 Devices at Once
    - Energy Saving Function (UPS Green Mode)
    - 50/60Hz Frequency Auto Sensing and Selection
    - USB Communication Port
    - Advanced Battery Management (ABM Technology)
Gneral
Sku
Backup Time
Net Weight Kg (lbs)
Digital Display
Output
Watts
UPS Capacity
No. of Sockets
Voltage (Battery)
Frequency (Battery)
Transfer Time
Input
Voltage (Single Phase)
Frequency
Protection
Unit Input
Overload Protection
Short Circuit
Surge Protection
Battery
Type
Typical Recharge Time
Protection
Interface
USB
Alarm
Battery Backup
Battery Low
Abnormal Charge
Overload
Environment Ambient Operation
1500VA
2000VA
ULT33045
ULT33046
About 60 Minutes
About 65 Minutes
Yes
Yes
900
1200
1500VA
2000VA
Style A UPSx4, Bypassx2
Style A UPSx4, Bypassx2
Simulated square wave output at nominal +/-5%
Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
2-4 milliseconds, including detection time
120V +15%/-20% at line input
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
Circuit breaker for overload & short circuit protection
UPS automatic power off if overload exceeds 110% of 
nominal at 60 seconds and 130% at 3 seconds
UPS automatic power off if overload exceeds 110% of 
nominal at 60 seconds and 130% at 3 seconds
UPS output shuts off immediately
UPS output shuts off immediately
2100 Joules
2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6 
years typical lifetime
Sealed, maintenance-free lead acid battery, with 3-6 
years typical lifetime
6 hours (to 90% of full capacity)
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short 
circuit protection by fuse
Automatic self-test, Over discharge protection, short 
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC 
input/output power status display.
Battery low detecting, UPS on/off scheduling AC 
input/output power status display.
Slow beeping sound every 4 seconds
Slow beeping sound every 4 seconds
Rapid beeping sound every second
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
AC Mode: Rapid beeping sound every 0.5 second
Continue beeping sound
Continue beeping sound
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30 ͠
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30 ͠
1000VA
1025VA
ULT31502
ULT33044
About 50 Minutes
About 50 Minutes
28.6(63.0)
28.6(63.0)
Yes
Yes
615
615
1025VA
1025VA
Style A UPSx4, Bypassx2
Style A UPSx4, Bypassx2
Simulated square wave output at nominal +/-5%
Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
2-4 milliseconds, including detection time
120V +15%/-20% at line input
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
Circuit breaker for overload & short circuit protection
UPS automatic power off if overload exceeds 110% of 
nominal at 60 seconds and 130% at 3 seconds
UPS automatic power off if overload exceeds 110% of 
nominal at 60 seconds and 130% at 3 seconds
UPS output shuts off immediately
UPS output shuts off immediately
2100 Joules
2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6 
years typical lifetime
Sealed, maintenance-free lead acid battery, with 3-6 
years typical lifetime
6 hours (to 90% of full capacity)
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short 
circuit protection by fuse
Automatic self-test, Over discharge protection, short 
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC 
input/output power status display.
Battery low detecting, UPS on/off scheduling AC 
input/output power status display.
Slow beeping sound every 4 seconds
Slow beeping sound every 4 seconds
Rapid beeping sound every second
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
AC Mode: Rapid beeping sound every 0.5 second
Continue beeping sound
Continue beeping sound
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30 ͠
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30 ͠
Includes
UPS Monitoring
Software