Panasonic PT-VX505NEA Manuale Utente

Pagina di 133
-42-
Electrical Adjustments
1. Fan voltage adjustment 
  Equipment 
Digital voltmeter
1. Enter the service mode.
2.  Adjust the voltage on each test point by changing the   
data values of Group - No.
  Group - No.   Test Points  Adjustment value
 
250  -  0
 
TPFANA 
3.5V+0.1,-0Vdc
 
250  -  1 
TPFANA  
13.8V+0,-0.1Vdc
 
250  -  2 
TPFANB 
3.5V+0.1,-0Vdc
 
250  -  3 
TPFANB 
13.8V+0,-0.1Vdc
 
250  -  4
 
TPFANC 
3.5V+0.1,-0Vdc
 
250  -  5
 
TPFANC 
13.8V+0,-0.1Vdc
 
250  -  6
 
TPFAND 
3.5V+0.1,-0Vdc
 
250  -  7
 
TPFAND 
13.8V+0,-0.1Vdc
 
250  -  8
 
TPFANE 
3.5V+0.1,-0Vdc
 
250  -  9
 
TPFANE 
13.8V+0,-0.1Vdc
 250  -  10
 
TPFANF 
4.5V+0.1,-0Vdc
 250  -  11
 
TPFANF 
13.8V+0,-0.1Vdc
 250  -  12
 
TPFANG 
4.5V+0.1,-0Vdc
 250  -  13
 
TPFANG 
13.8V+0,-0.1Vdc
3. Auto calibration adjustment [PC]
  Input mode 
Computer 1 (RGB)
  Input signal 
XGA Computer signal
  Signal pattern 
16-step gray scale     
1. Enter the service mode.
2.  Select Group “
260
”, No. “
0
” and set the data value 
to  “
1
”.
   The projector begins auto-calibration and then "OK" 
will appear on the screen.
  Adjustments item no. [3] and [5] are carried out 
at the spare parts shipment in the factory, there-
fore they are not required when the MAIN board is 
replaced with new one.
2. Panel type check and setting
*  Before setting, you need to check which type of LCD panel 
is placed on the projector according to the item “LCD pan-
el/prism assy removal” in the chapter “Optical Parts Disas-
sembly”.
1. Enter the service mode.
2. Panel type check
Select Group "290",No. "0" check the data value as fol-
lows;
    Data value: 0               For L-type of LCD panel
    Data value: 20             For R-type of LCD panel
If the mounted LCD panel type and set panel mode are 
differ, take the step below.
3. Panel type mode setting
Select  Group  "290",  No.  "1"  and  change  data  value 
from 10 to 0 or 20 depending on your LCD panel type. 
When the data value reaches 0 or 20, it returns to 10 
quickly. The gamma-characteristics changes according  
to your selection.
4. Auto calibration adjustment [Component]
  Input mode 
Computer 1 (Component)
  Input signal 
480i component signal
  Signal pattern 
8 color 100% color bar 
1. Enter the service mode
2.  Select Group “
260
”, No. “
0
” and set the data value 
to  “
1
”.
   The projector begins auto-calibration and then "OK" 
will appear on the screen.
5. Auto calibration adjustment [Video]
  Input mode 
Video
  Input signal 
Composite video signal
  Signal pattern 
16-step gray scale
1. Enter the service mode. 
2.  Select  Group  “
260
”,  No.  “
0
”  and  then  change  data 
value from “
0
” to “
1
”. After the auto-calibration com-
pleted, “
OK
” will appear on the screen.