Promise Technology m210p Manuale Utente

Pagina di 262
VTrak M310, M210p Product Manual
214
Cache policy is in 
writeback mode without 
battery  
Install or replace the battery. See page 175.
Blowers
Blowers have started
Normal.
Blowers have stopped
Verify that the cooling unit is properly installed. If the 
blower still does not turn, replace the blowers. See 
page 172.
Blower speed is 
increased
Check the VTrak for overheating. See page 231.
Blower speed is 
decreased
Temporary overheat condition was corrected.
Blowers are NOT 
functioning
Replace the blowers. See page 172.
Blowers have been 
inserted
Normal.
Blowers have been 
removed
Reinstall the cooling unit(s). If the blowers does not 
turn, replace the blowers. See page 172.
Blowers are functioning 
normally
Normal.
Blowers are NOT installed Reinstall the cooling unit(s). If the blowers does not 
turn, replace the blowers. See page 172.
Blower status is unknown Check for airflow out of the cooling unit. If there is 
none, check for proper installation.
Cache
BBU flushing has started
VTrak’s cache is being flushed.
BBU flushing has ended
VTrak’s cache has been flushed.
BBU flushing has failed
VTrak’s cache could not be flushed. Check your 
cache flush interval setting. See page 80.
Controller
The controller 
parameter(s) changed by 
user
The user successfully change controller settings. See 
page 80.
The controller is reset by 
Watch Dog timer
The Watch Dog timer has started.
Event
Action