FUNCTION: Offset
DESCRIPTION:
The OF command sets a bias voltage in the motor command output or returns a previously set
value. This can be used to counteract gravity or an offset in an amplifier. If the PID
values are zero, then the output voltage will be the OF value. The OF command works in
servo mode only.
values are zero, then the output voltage will be the OF value. The OF command works in
servo mode only.
ARGUMENTS: OF n
where
n is a signed number in the range -9.998 to 9.998 volts with resolution of .0003.
“?” returns the offset
USAGE:
While Moving
Yes
Default Value
0
In a Program
Yes
Default Format
1.4
Command Line
Yes
Can be Interrogated
Yes
Used as an Operand
Yes
Controller Usage
ALL
OPERAND USAGE:
_OF contains the offset.
EXAMPLES:
OF 1
Set offset to 1
OF ?
Return offset
1.0000