Galil DMC-1400 Manuale Utente
70 ● DT
DMC-1400 Series Command Reference
DT
FUNCTION: Delta Time
DESCRIPTION:
The DT command sets the time interval for Contouring Mode. Sending the DT command
once will set the time interval for all following contour data until a new DT command is
sent. 2n samples is the time interval. Sending DT0 followed by CD0 command
terminates the Contour Mode.
sent. 2n samples is the time interval. Sending DT0 followed by CD0 command
terminates the Contour Mode.
ARGUMENTS: DT n
where
n is an integer in the range 0 to 8. 0 terminates the Contour Mode. n=1 thru 8 specifies the
time interval of 2n samples. By default the sample period is 1 msec (set by TM
command); with n=1, the time interval would be 2 msec.
command); with n=1, the time interval would be 2 msec.
DT? Returns the value for the time interval for contour mode.
USAGE:
While Moving
Yes
Default Value
0
In a Program
Yes
Default Format
1.0
Command Line
Yes
Can be Interrogated
Yes
Used as an Operand
Yes
Controller Usage
ALL
OPERAND USAGE:
_DT contains the value for the time interval for Contour Mode
RELATED COMMANDS:
Contour Mode
Contour Data
Wait for next data
Time
EXAMPLES:
DT 4
Specifies time interval to be 16 msec
DT 7
Specifies time interval to be 128 msec
#CONTOUR Begin
CM Enter
CM Enter
Contour
Mode
DT 4
Set time interval
CD 1000
Specify data
WC
Wait for contour
CD 2000
New data
WC Wait
DT0 Stop
DT0 Stop
contour
CD0
Exit Contour Mode
EN End