Galil DMC-1400 Manuale Utente

Pagina di 235
70 ● DT   
 
 
 
 
 
   DMC-1400 Series Command Reference 
DT  
FUNCTION:  Delta Time 
DESCRIPTION: 
The DT command sets the time interval for Contouring Mode.  Sending the DT command 
once will set the time interval for all following contour data until a new DT command is 
sent.  2n samples is the time interval.  Sending DT0 followed by CD0 command 
terminates the Contour Mode. 
ARGUMENTS:  DT n 
where  
n is an integer in the range 0 to 8.  0 terminates the Contour Mode.  n=1 thru 8 specifies the 
time interval of 2n samples.  By default the sample period is 1 msec (set by TM 
command);  with n=1, the time interval would be 2 msec. 
DT? Returns the value for the time interval for contour mode. 
USAGE: 
While Moving 
Yes 
Default Value 
In a Program 
Yes 
Default Format 
1.0 
Command Line 
Yes 
 
 
Can be Interrogated 
Yes 
 
 
Used as an Operand 
Yes 
 
 
Controller Usage 
ALL 
OPERAND USAGE: 
_DT contains the value for the time interval for Contour Mode 
RELATED COMMANDS: 
Contour Mode 
CD  
Contour Data 
Wait for next data 
Time 
EXAMPLES: 
DT 4 
Specifies time interval to be 16 msec 
DT 7 
Specifies time interval to be 128 msec 
#CONTOUR Begin 
CM Enter 
Contour 
Mode 
DT 4 
Set time interval 
CD 1000 
Specify data 
WC 
Wait for contour 
CD 2000 
New data 
WC Wait 
DT0 Stop 
contour 
CD0 
Exit Contour Mode 
EN End