Galil DMC-1400 Manuale Utente

Pagina di 235
DMC-1400  Series Command Reference EN 
● 81   
EXAMPLES: 
#A Program 
PR 500 
Move X axis forward 500 counts 
BGX 
Pause the program until the X axis completes the motion 
AMX 
Move X axis forward 1000 counts 
PR 1000 
Set another Position Relative move 
BGX Begin 
motion 
EN 
End of Program 
 
Note:  Instead of EN, use the RE command to end the error subroutine and limit subroutine.  Use the 