Galil DMC-1400 Manuale Utente
DMC-1400 Series Command Reference EN
● 81
EXAMPLES:
#A Program
A
PR 500
Move X axis forward 500 counts
BGX
Pause the program until the X axis completes the motion
AMX
Move X axis forward 1000 counts
PR 1000
Set another Position Relative move
BGX Begin
motion
EN
End of Program
Note: Instead of EN, use the RE command to end the error subroutine and limit subroutine. Use the
RI command to end the input interrupt (ININT) subroutine.
RI command to end the input interrupt (ININT) subroutine.