Cabletron Systems STS16-20D Manuale Utente

Pagina di 258
134
SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide
Switch Configuration
1200, 2400, 4800, 9600, 19200, 38400, 57600, or Autobaud. The default value for 
this parameter is 9600. Make sure that your terminal emulator baud rate matches 
the console baud rate you set.
Creating a Console Session Using a Modem
Use the Serial Link Configuration menu to configure the SmartStack STS16-
20D/STS16-20R in order to communicate with a console via a modem.
Set your modem according to the following table:
Caution:
 Some modems use slightly different names for the options. It is important 
that your modem be configured correctly. The settings shown in italics are 
particularly important. If your modem is not configured correctly, the connection 
may cause the SmartStack STS16-20D/STS16-20R to reset.
Start the console by pressing 
ENTER
. If a Telnet session is active, press 
ENTER
 at 
the console to terminate the Telnet session and press 
ENTER
 again to start the 
console session.
Stopping the Console Session
Pressing 
CTRL-P
 returns the console session to the main menu, and pressing 
CTRL-
B
 returns to the greeting menu.
Setting
Value
Echo
Off
Result codes
Off
Wait for connection
45 seconds
Pause between calls
6 seconds
Drop DTR between calls
Yes
Send CR between calls
Yes
Auto baud detect
On
Send init if CD high
Yes
Maximum dial attempts
999
Table 14.  Modem Settings