Cabletron Systems STS16-20D Manuale Utente

Pagina di 258
152
SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide
Switch Configuration
Reset Screen
To open this screen, select Reset... in the main menu. This screen displays the reset 
options available with the switch.
 
Number of Resets Since Diagnostics
Number of times the switch has been reset since the switch was powered on or ran 
power-on diagnostics. This is an informational heading; the data cannot be changed.
This number is not reset to 0 when nonvolatile RAM is cleared.
The following four items within the Reset screen are command functions that you 
can select and initiate by moving the highlight over the item and pressing 
ENTER.
Reset Switch With Diagnostics
A reset function is initiated with this command. It resets the switch hardware; runs 
diagnostic tests; clears all counters, including address tables; and restarts the 
SmartStack STS16-20D/STS16-20R. When the SmartStack STS16-20D/STS16-
20R reboots, administrative parameters from nonvolatile memory are used to 
initialize the operational parameters. This takes approximately 4 to 5 minutes.
Reset Switch Without Diagnostics
This command resets the switch hardware; clears all counters, including address 
tables; and starts the SmartStack STS16-20D/STS16-20R. When the SmartStack 
STS16-20D/STS16-20R reboots, administrative parameters from nonvolatile 
memory are used to initialize the operational parameters. This procedure takes 
approximately 40 seconds.