2-1-4-2. Configuring the Management Agent of 
 
MSM-6226 through the 
Ethernet Port
  
There  are  three  ways  to  configure  and  monitor  the  switch  through  the 
switch’s  Ethernet  port.  They  are  CLI, Web  browser  and  SNMP  manager.  The  user 
interface  for  the  last  one  is  NMS  dependent  and  does  not  cover  here.  We  just 
introduce the first two types of management interface. 
 
 
 
 
 
 
                                            
 
 
 
 
 
 
 
 
••
• 
  
 
Managing 
 
MSM-6226 through Ethernet Port 
           
Before  you  communicate  with  the  switch,  you  have  to  finish  first  the            
configuration of the IP address or to know the IP address of the switch. Then, 
follow the procedures listed below. 
1.  Set up a physical path between the configured the switch and a PC by a 
qualified UTP Cat. 5 cable with RJ-45 connector. 
Note:  If  PC  directly  connects  to  the  switch,  you  have  to  setup  the  same 
subnet mask between them. But, subnet mask may be different for the PC 
in  the  remote  site.  Please  refer  to  Fig.  2-9  about  the  switch’s  default  IP 
address information. 
2.  Run CLI or web browser and follow the menu. Please refer to Chapter 3 
and Chapter 4. 
 
               Fig. 2-10 the Login Screen for Web 
 
MSM-6226 L2 Managed Switch   
Default IP Setting: 
IP = 192.168.1.1 
Subnet Mask = 255.255.255.0 
Default Gateway = 192.168.1.254 
 
Assign a reasonable IP address, 
For example: 
IP = 192.168.1.100 
Subnet Mask = 255.255.255.0 
Default Gateway = 192.168.1.254 
Fig. 2-9 
    Ethernet LAN