Interrupts 
INT * 
Usage 
/INT1, /INT2 
IUSC logically or-ed interrupts. IUSC Interrupts can be muxed to any of the two INTs.  
One use is to mux all ports configured for Async mode to one IRQ and all ports 
configured for Sync mode to another interrupt. This should facilitate better software 
architecture and operation. 
/INT3 
PLD Interrupt. To support miscellaneous PLD section functions. 
/INT6 
Ethernet PHY Interrupt. Same PHY as other MCF5272 based Blue Heat/Net models. 
* INTs are active low. Unused interrupts are pulled up to V+. 
 
Table 6: Interrupts 
 
 
 
 
 
ColdFire MCF5272 GPIO
 
GPIO Bit(s) * 
Direction 
Usage 
PA0 – PA4, 
PA6 
Undefined 
Undefined. For future expansion or debugging purposes. Available on 
debug header P11 on page 8 of Schematic 
PA5 
Output 
CPU Status LED.  
1 = LED Off 
0 = LED On. 
PA8 – PA11 
Input 
PCB ID. Should be 0x4, for BHN Sync 4 Port. 
PA13 
Input 
Pushbutton input.  
1 = not pushed 
0 = pushed 
PA14 
Output 
Software forced hardware reset.   
1 = Not reset. When setting up this GPIO, be sure to set port to a „1‟ 
before changing direction to output. 
0 = forces a hardware reset 
Table 7: ColdFire MCF5272 GPIO 
* All unused GPIO is pulled up with a pullup resistor. 
 
Base Address Map 
Item 
Address Range (hex) 
ColdFire MBAR 
1000 0000 
Internal SRAM (4k Byte) 
2000 0000 
IUSC 0  
4000 0000 
IUSC 1 
4000 0400 
IUSC 2 
4000 0800 
IUSC 3 
4000 0C00 
PLD registers 
4000 1000 
DPR (32k Byte SRAM) 
8000 0000 
Flash (8 M Byte ) 
FE00 0000 
 
 
 
Table 8: Base Address Map