Equipment and Resource Provisioning
addapsln
addapsln
Add APS Line
Creates (designates) a pair of lines (workingIndex, protectIndex) as APS lines. To configure the APS 
parameters, use the cnfapsln command after creating the lines using the addapsln command.
APS Overview
Automatic Protection Switching (APS) is a standards-based redundancy scheme which enhances 
network reliability by protecting against line failure. APS is defined in Bellcore and ITU standards for 
North American SONET and international Synchronous Data Hierarchy (SDH) optical network links. 
The relevant standards are Bellcore GR-253 and ITU-T G.783.
APS enables a pair of SONET lines to be configured for line redundancy. The APS pair consists of a 
working line (workingIndex) and a protection line (protectIndex), where one line is active and the other 
is a backup. Whether or not the backup line passes real traffic while in standby mode depends on the 
APS architecture mode (archmode).
Coordination of line switching is controlled by an in-band signaling protocol. If the fiber optic carrier 
for the active line is severed or damaged, the in-band signaling protocol must detect the fault within 10 
milliseconds. After the in-band signaling protocol has detected the fault, it must switch the user traffic 
to the standby line within 50 milliseconds.
When the revertive option is enabled (see cnfapsln), the in-band signaling protocol will attempt to 
switch the user traffic back to the working line from the protection line after the working line becomes 
functional again. However, it must wait for the configured time period (wait to restore) to elapse.
Direction
APS can be configured in two directions (see direction parameter in cnfapsln), bidirectional and 
unidirectional. Bidirectional means that both the receiving and transmitting paths are switched. 
Unidirectional means that only the affected path, receiving or transmitting, is switched.
Same-card APS
In same-card APS, the working bay and protection bay must be the same, and the working line and 
protection line must be adjacent. 
Architecture mode 1:1 is supported only on same-card APS. 
Cross-card APS
In cross-card APS, the working bay and line number, and the protection bay and line number must be 
the same. The working slot and the protection slot must be adjacent. Card redundancy must be 
configured on the two cards before cross-card APS can be added.
Architecture modes 1+1, Annex 1+1, and Straight 1+1 Nok1k2 are supported on same-card as well as 
cross-card APS.
APS Architecture Modes (archmode)
The MGX 8850 supports two architecture modes. You must select one of these architecture modes in the 
archmode parameter when you execute the addapsln command.
APS 1:1—provides line redundancy with traffic on the active line only 
APS 1+1—provides line redundancy with traffic on both lines