cnfsig
cnfsig
Configure Signaling—configures signaling timers and crankback attempts for a port.
The cnfsig command lets you configure signaling timers for a port whether the port is up or down. The 
new configuration applies to new incoming calls while existing calls remain intact. In addition to 
standard timers, this command lets specify the maximum number of crankbacks that PNNI can attempt 
at a port. You must specify at least one of the optional parameters. 
Cards on Which This Command Runs
PXM45 
Syntax
cnfsig <portid> 
[-t301 t301-timer ] 
[-t303 t303-timer ] 
[-t308 t308-timer
 
[-t310 t310-timer
 
[-t316 t316-timer
 
[-t317 t317-timer
 
[-t322 t322-timer
 
[-t397 t397-timer
 
[-t398 t398-timer ] 
[-t399 t399-timer
 
[-maxcrbk value
 
]
Syntax Description
portid
The portid is the PNNI physical port. The format is 
[shelf.]slot[:subslot].port[:subport]. See also 
.
-t301 
The T301 timer. 
Range: 150–240 seconds
Default: 180
-t303 
The T303 timer. 
Range: 4–8 seconds
Default: 4
-t308 
The T308 timer. 
Range: 20–45 seconds 
Default: 30