B – Command Line Interface
Reset Command
59021-05 B
B-19
Q
Reset Command
Resets the switch configuration parameters.
Authority
Admin
Syntax
reset
config [config_name]
factory
port [port_number]
snmp
switch (default)
system
zoning
Keywords
config [config_name]
Resets the configuration given by [config_name] to the factory default values for 
switch, port, alarm threshold, and zoning configuration. This keyword clears all 
zoning definitions. If [config_name] does not exist on the switch, a configuration 
with that name will be created. If you omit [config_name], the active configuration 
is reset. You must activate the configuration or reset the switch for the changes to 
take effect. Refer to 
 throug
 for switch, port, and alarm 
threshold configuration default values.
factory
Resets switch, alarm threshold, zoning, SNMP, zoning configuration, and system 
configuration settings to the factory default values. The switch configuration is 
activated automatically. Refer to 
port [port_number]
Reinitializes the port given by [port_number]. Ports are numbered beginning 
with 0.
snmp
Resets the SNMP configuration settings to the factory default values. Refer to 
 for SNMP configuration default values.
switch
Reinitializes the switch. This is the default. This command also closes the Telnet 
session.
system
Resets the system configuration settings to the factory default values. Refer to 
 for system configuration default values.
zoning
Clears the zoning database and deactivates the active zone set. The zoning 
configuration values (autosave, default visibility) remain unchanged.
Notes
The following tables specify the various factory default settings: