2 – General Description
Chassis Controls and LEDs
59042-07 A
2-3
0
2.1.1
Maintenance Button
The Maintenance button is a dual-function momentary switch on the front panel. 
Its purpose is to reset the switch or to place the switch in maintenance mode. 
Maintenance mode sets the IP address to 10.0.0.1 and provides access to the 
switch for maintenance purposes when flash memory or the resident configuration 
file is corrupted. Refer to 
for more information 
about using maintenance mode.
2.1.1.1
Resetting a Switch
To reset the switch, use a pointed tool to momentarily press and release (less than 
2 seconds) the Maintenance button. The switch will respond as follows:
1.
All of the chassis LEDs will illuminate and then extinguish leaving only the 
Input Power LED illuminated.
2.
After approximately 1 minute, the Power-On Self Test (POST) begins 
illuminating all chassis LEDs.
3.
When the POST is complete, the chassis LEDs extinguish leaving the Input 
Power LED illuminated and the Heartbeat LED flashing once per second.
2.1.1.2
Placing the Switch in Maintenance Mode
To place the switch in maintenance mode, do the following:
1.
Isolate the switch from the fabric.
2.
Press and hold the Maintenance button with a pointed tool for 2–4 seconds. 
When the Input Power LED alone is illuminated, release the button.
3.
After approximately 1 minute, the POST begins illuminating all chassis 
LEDs.
4.
When the POST is complete, the chassis LEDs extinguish leaving the Input 
Power LED and the Heartbeat LED illuminated. The Heartbeat LED 
illuminates continuously while the switch is in maintenance mode.
To exit maintenance mode and return to normal operation, momentarily press and 
release the Maintenance button to reset the switch.