3 – Managing Fabrics
Zoning a Fabric
3-12
59022-03 D
3.4.1.3
Zone Sets
A zone set is a named group of zones. A zone can be a member of more than one 
zone set. All zones that are not members of a zone set belong to the orphan zone 
set. The orphan zone set is saved to the switch. Each switch in the fabric 
maintains its own zoning database containing one or more zone sets. This zoning 
database resides in non-volatile or permanent memory and is therefore retained 
after a reset. Refer to 
 for 
information about displaying the zoning database.
To apply zoning to a fabric, choose a zone set and activate it. When you activate a 
zone set, the switch distributes that zone set to every switch in the fabric. 
Therefore, every switch in the fabric will have identical active zone sets. Refer to 
 for information about displaying the 
active zone set.
3.4.1.4
Zoning Database
Each switch has its own zoning database. The zoning database is made up of all 
aliases, zones, and zone sets that have been created on the switch or received 
from other switches. The switch maintains two copies of the zoning database: one 
copy is maintained in temporary memory for editing purposes; the second copy is 
maintained in permanent memory. When you modify aliases, zones, and zone 
sets, these changes are made to the temporary zoning database. If you reset the 
switch or lose power to the switch before saving the permanent zoning database, 
the changes will be lost.
The Auto Save zoning configuration parameter controls whether the temporary 
zoning database is automatically saved in permanent memory. Refer to 
 for more information about the Auto Save 
parameters.