National Instruments 653X Manuale Utente

Pagina di 147
Chapter 3
Timing Diagrams
© National Instruments Corporation
3-9
Figure 3-6. Burst Output Timing Diagram (Default)
Parameter
Description
Minimum
Maximum
Input Parameters
t
pc
PCLK cycle time
50
t
pw
PCLK high pulse duration
20
t
pl
PCLK low pulse duration
20
t
rs
Setup time from REQ valid to PCLK
falling edge
1
t
rh
Hold time from PCLK to REQ invalid
0
Output Parameters
t
pa
PCLK to ACK valid
22
t
ah
Hold time from PCLK to ACK invalid
3
t
pdo
PCLK to output data valid
28
t
doh
Hold time from PCLK to output data
invalid
5
All timing values are in nanoseconds.
PCLK
ACK
Data Out Valid
REQ
t
rs
t
pa
t
pdo
t
pw
t
pl
t
pc
t
rh
t
ah
t
doh