CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
Preparing for Installation
Site Requirements
Following are the site requirements for installation.
Environment
Choose a clean, dust-free, (preferably) air-conditioned location. Avoid direct 
sunlight, heat sources, or areas with high levels of EMI (Electromagnetic 
Interference).
Chassis Accessibility
Make sure the front and back panel of the equipment is accessible so that you can 
monitor the LED indicators and access the control switches. Leaving enough 
clearance at the front and back will also allow easier cabling and service.
Cooling and Airflow
Two fans, which are located at the left side of the switch, cool the interior by 
drawing air through vents on the left side and forcing heated air out through holes 
in the right side. If the internal temperature exceeds 50°C (112°F), a temperature 
error is reported to the console.
Caution: To protect the equipment from overheating, do not operate it in an area 
that exceeds the maximum recommended ambient temperature of 40°C (104°F). To 
prevent airflow restriction, you must allow at least 7.6 cm (3") of clearance around 
chassis openings for proper airflow.
Power
The source electrical outlet should be installed near the switch, be easily accessible, 
and be properly grounded.
Alsoobserve the following power cable considerations before you begin 
installation of the CrossFire 8600 Token-Ring Switch and/or the CrossFire 8605 
Token-Ring Fiber Switch.
1. The socket outlet shall be installed near the equipment and shall be easily 
accessible.
2. To prevent electrical shock, the power cord set used must comply with national 
regulations.
2a. The female receptacle of the cord must meet CEE-22 requirements.