Enterasys Networks 6000 Manuale Utente

Pagina di 231
Alarm Configuration
4-6
Basic Alarm Configuration
The remainder of the window fields provide the means for configuring alarms for each 
available interface. Note that the information provided in this screen is static once it is 
displayed; for updated information, click on the Refresh button. Adding or modifying an 
alarm automatically updates the list.
Creating and Editing a Basic Alarm
The editable fields at the bottom of the Basic Alarm Configuration window allow you to 
configure alarm parameters for each available interface. These fields will display the 
parameters used for the most recently configured alarm (no matter which interfaces are 
selected in the list box); this allows you to set the same parameters on multiple interfaces 
with a single set. Hold down the Shift key while clicking to select a contiguous group of 
interfaces; use the Ctrl key to select any interfaces. To display the alarm parameters for a 
specific interface, double-click on that interface. 
Note that there is no specific “Enable” function; simply configuring thresholds and/or 
actions for an alarm and applying those changes enables the alarm. For details on 
disabling an alarm, see 
, on 
.
To configure an alarm:
1.
At the top of the window, click to select the variable to be used for your alarm: 
Kilobits
Total Errors, or Broadcast/Multicast. The display in the list box 
will reflect the current status at each interface of the alarm type you have 
selected.
2.
In the list box, click to highlight the interface (or use shift-click or ctrl-click to 
select multiple interfaces) for which you would like to configure an alarm for 
the selected variable. Note that the editable fields will display the parameters 
assigned to the most recently set alarm; however, any changes you make in 
these fields will be set to
 all selected interfaces.
3.
In the Interval field, enter the amount of time, in days, hours, minutes, and 
seconds, over which the selected variable will be sampled. At the end of the 
interval, the sample value will be compared to both the rising and falling 
thresholds. You can assign any time interval up to 24,855 days. If you set an 
incorrect time value (e.g., you enter 75 minutes instead of 1 hour, 15 minutes) 
you will receive an error message. Click OK and enter the correct time value.
TIP
Before you decide whether or not to assign an action to a rising or falling alarm, it is 
important to understand something about the hysteresis function built in to the RMON 
alarm functionality. See 
, on 
, for 
more information.