Power Save Mode
In power save (standby) mode, all non-essential hardware is shut down in order to 
conserve power. 
• 
To enable power save mode, enter the Power Save ON SIS command (see the 
• 
To exit power save mode, either enter the Power Save OFF SIS command or press 
any front panel button (if the front panel is locked, this method does not work).
NOTE:  The backup and restore functions available through the PCS control software 
are not accessable while the unit is in power save mode.
Presets
A preset is a set of input parameters that are either saved by you or automatically by 
the DSC as a files in DSC memory. Saved presets can be recalled and their settings 
implemented at any time. A preset saves time by enabling you to apply a group of settings 
to the DSC at one time. 
The DSCs have three types of presets: Auto Memories, user presets, and global input 
presets. 
Auto Memories
The DSC has 32 memory locations in which the current input configuration and picture 
control values are automatically stored as an input preset, when Auto Memory is enabled. 
An Auto Memory preset is recalled when an identical input resolution and rate is applied to 
the input.
Each Auto Memory preset is stored with a time stamp that is incremented each time its 
stored rate is detected. If all Auto Memory slots are occupied and a new rate is applied, 
the Auto Memory with the oldest time stamp is overwritten. 
Auto memory can be enabled using the OSD (see the 
Advanced
 submenu on page 33) and by SIS commands (see the 
commands on page 53).
The following information is stored in an Auto Memory preset:
  Contrast
  Active lines (V Active)
  Brightness
  Horizontal image position
  Detail
  Vertical image position
  Horizontal start
  Horizontal image size (width)
  Vertical start
  Vertical image size (height)
  Active pixels (H Active)
  Total pixels
DSC 3G-HD A and DSC HD-3G A • Operation