Extron electronic 128 Manuale Utente

Pagina di 104
3-21
CrossPoint 300 Matrix Switchers • Operation
Example 6: Saving a preset
The following steps show an example in which the current configuration is saved
as a preset in a CrossPoint 300  1616.  The steps show the front panel indications
that result from your actions.
1
.
Press and release the Esc button (figure 3-33).
ENTER PRESET VIEW
ESC
CONTROL
Press the Esc button to clear all selections.
The LED 
blinks once.
Figure 3-33 — Clear all selections
2
.
Press and hold the Preset button for approximately 2 seconds until the Preset
LED blinks (figure 3-34).
PRESET
1
2
3
4
Press and hold the Preset button until 
the Preset LED blinks.
If you then save the configuration to a lit preset number,
the configuration data at that preset location will be overwritten.
Lit
(Preset Assigned)
Unlit
(Preset Unassigned)
Preset 17
Preset 18
Preset 20
Preset 19
All input and output LEDs with 
assigned presets light.
Figure 3-34 — Enter Save Preset mode
3
.
Press and release the Output 1 button (figure 3-35).
ENTER PRESET VIEW
CONTROL
1
2
3
4
The Enter LED blinks to indicate 
the need to save the preset.
The Preset LED continues to blink.
Press and release the Output 1 button.
The LED blinks to indicate that this preset 
number is selected but not saved.
Preset 17
Preset 18
Preset 20
Preset 19
Figure 3-35 — Select the preset