Repeat steps 
4
Slide the EPS-C into a 19-inch rack and secure it using appropriate rack-mount screws.
5
Connect the keyed end of the redundant power cord to the EPS-C (see 
). Verify that the 
side of the connector marked TOP is facing up. 
The key is a plastic tab on the cable connector housing that fits into the EPS-C to ensure correct 
alignment of the connector. 
6
Connect the other end of the redundant power cord to the Summit X450e-48p or X250e-48p switch 
(see 
). Be sure that the side of the connector marked TOP is facing up.
Figure 163: Installing the Redundant Power Cord
Installing an EPS-600LS Power Supply
To install an EPS-600LS unit into an EPS-C:
1
If necessary, remove a cover plate from a slot in the EPS-C.
2
Slide the EPS-600LS into an empty slot in the EPS-C (see 
). 
CAUTION
Be sure that empty slots in the EPS-C chassis are always covered by a cover plate when not in use. The EPS-C is 
shipped with slots 2 and 3 covered and slot 1 open. Extreme Networks recommends that you populate slot 1 
with an EPS-600LS unit first, but this is not required. You can install EPS-600LS units into any of the slots in 
the EPS-C. The installation sequence does not affect the performance of the power supply units, but empty slots 
must be covered at all times. 
EPS-C_03A
Redundant Power Output
! See Manual
Connect First