Servis FS-1016MT Manuale Utente
8
DIP Switch Settings
The factory default settings are as follows:
1 2 3 4 5 6 7 8
ON
OFF
(*Note: the indicates the switch position)
DIP Switch Functions
SW
Function
ON state / OFF state
1
Hot Key Mode: <Ctrl>+<Alt>+<Shift>
ON: enabled / OFF: disabled
2
Hot Key Mode: Double <Ctrl>
ON: enabled / OFF: disabled
3
Hot Key Mode: Double <Scroll Lock>
ON: enabled / OFF: disabled
4
Country Setting bit 1
(see following table)
5
Country Setting bit 2
( “ )
6
Country Setting bit 3
( “ )
7
Country Setting bit 4
( “ )
8
Power Mode Setting
ON:
the switch device is always ON.
OFF: the switch device turns ON if any connected
host is turned ON.
The country code (language) settings are as follows: For Sun Microsystems plat home only
Country Setting
SW4 SW5 SW6 SW7
JPN
ON ON ON ON
USA
ON ON ON OFF
GBR
ON ON OFF ON
GER
ON ON OFF OFF
FRA
ON OFF ON ON
ESP
ON OFF ON OFF
SWE
ON OFF OFF ON
POR ON
OFF
OFF
OFF
TPE
OFF ON ON ON
KOR
OFF ON ON OFF
ITA
OFF ON OFF ON
UNIX
OFF ON OFF OFF
NOR
OFF OFF ON ON
BEL
OFF OFF ON OFF
DEN
OFF OFF OFF ON
Switching the KVM While Using SUN Hosts
When using only Sun hosts, you can change KVM switches without turning off the power to a Sun host.
Disconnect the connector from the KVM side only when changing them. Leave the host side
connectors attached(This function is available for USB interface only).
Note: When using PC/AT hosts, if all connections are USB type, you can similarly change KVM
switches without turning off the power to the hosts.
Disconnect the connector from the KVM side only when changing them. Leave the host side
connectors attached(This function is available for USB interface only).
Note: When using PC/AT hosts, if all connections are USB type, you can similarly change KVM
switches without turning off the power to the hosts.