Barco 26-0507000-00 Manuale Utente
18
BlendPRO-II • User’s Guide
2. Hardware Orientation
BlendPRO-II Rear Panel
3) Serial
Port
One 9-pin D connector is provided for RS-232 serial communications with
BlendPRO-II, typically for diagnostic purposes. The port is configured as a DCE,
115K Baud, 8 data bit, 1 stop bit, and no parity bits. The port can be connected to
a standard PC serial port with a straight through DB-9 to DB-9 cable.
BlendPRO-II, typically for diagnostic purposes. The port is configured as a DCE,
115K Baud, 8 data bit, 1 stop bit, and no parity bits. The port can be connected to
a standard PC serial port with a straight through DB-9 to DB-9 cable.
In Appendix A, refer to the “
” section on page 40 for pinouts.
4) AC
Connector
One AC Connector is provided for connecting BlendPRO-II to your facility’s AC
power source. The integral switch turns the chassis on and off.
power source. The integral switch turns the chassis on and off.
5) Inputs
Section
The figure below illustrates the Inputs Section:
Figure 2-2. BlendPRO-II Inputs Section
The Inputs Section includes four DVI digital inputs per DDWG 1.0 specifications.
All four are DVI-D (digital, single link, receptacle) using DVI-I connectors to allow
flexible cabling choices. Please note:
All four are DVI-D (digital, single link, receptacle) using DVI-I connectors to allow
flexible cabling choices. Please note:
~
Each input accepts DVI progressive RGB signals with a pixel clock
speed from 25 - 162MHz (1600x1200x60Hz).
speed from 25 - 162MHz (1600x1200x60Hz).
~
Each input must be of the same resolution and H/V locked together.
In Appendix A, refer to the “
” section on page 38 for
pinout details.
INPUTS
1
2
3
4