Milan Technology E-FX-HB-0800 Manuale Utente

Pagina di 8
INSTALLATION 
Optionally Install Expansion Adapter
WARNING: Remove AC line cord from power source before installing
expansion adaptor in E-FX-HB-xx00. Failure to observe this warning could
result in personal injury or death.
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing Expansion Adapter in the E-FX-HB-xx00. Failure
to observe this caution could result in damage to, and subsequent failure of,
Expansion Adapter.
To install the expansion adapter in the E-FX-HB-xx00:
1.
Locate expansion adapter plate at back of E-FX-HB-xx00.
2.
Remove expansion adapter plate by using flatblade screwdriver to
remove two (2) screws that secure expansion adapter plate to back
of E-FX-HB-xx00.
NOTE: Retain screws for step 5. (Optionally discard expansion
adapter plate.)
3.
Carefully slide expansion adapter, component side up, into
installation space revealed by removal of expansion adapter plate.
CAUTION: Do NOT force the connection. Failure to observe this
caution could result in equipment damage and subsequent failure.
4.
Press component on expansion adapter securely against internal
mating E-FX-HB-xx00 component until expansion adapter faceplate
is flat against E-FX-HB-xx00 chassis.
5.
Secure expansion adapter by installing retained screws through
expansion adapter into E-FX-HB-xx00 chassis.
YES
Continue at step 7.
7.
Is one (or more) of the 100BASE-FX STAT(us) LEDs illuminated
continuously?
YES
Continue at step 10
NO
Continue at step 8.
8.
Does one (or more) of the 100BASE-FX STAT(us) LEDs blink on
and off?
YES
Check fiber cables for proper connection.
Verify that TX and RX cables on E-FX-HB-xx00 are connected to RX
and TX ports, respectively, on terminal device. (See page 9.)
Ensure that terminal device(s) is/are powered.
Contact Technical Support: (800) 260-1312.
NO
Continue at step 9.
9.
Is one (or more) of the 100BASE-FX STAT(us) LEDs dark?
YES
The port is (or ports are) partitioned; investigate the attached
terminal device(s).
Contact Technical Support: (800) 260-1312.
NO
Continue at step 10.
10.
Is one (or more) of the 100BASE-FX ACT(ivity) LEDs
illuminated?
YES
The port is (or ports are) operational and receiving data.
NO
Disconnect and reconnect the 100BASE-FX cable to restart the
initialization process.
Restart the terminal device(s) to restart the initialization process.
Contact Technical Support: (800) 260-1312.
Expansion Adapter Plate