Chapter 6
Cajun Campus CLI – Layer 2
90
Cajun P332MF User’s Guide
Example:
Cajun_P330-N# rmon history 1026 1026 interval 30 buckets 20
owner amir
history 1026 was created successfully
Cajun_P330-N# rmon history 1026 1026 interval 30 buckets 20
owner amir
history 1026 was created successfully
Rmon alarm Command
Use the
rmon alarm command to create a new RMON alarm entry.
The syntax for this command is:
rmon alarm <Alarm Number> <variable> <interval> <sampletype>
rising-threshold <rising threshold> <rising event> falling-
threshold <falling threshold> <falling event> <startup alarm>
<owner>
rmon alarm <Alarm Number> <variable> <interval> <sampletype>
rising-threshold <rising threshold> <rising event> falling-
threshold <falling threshold> <falling event> <startup alarm>
<owner>
interval
The interval between 2 samples
number of buckets
The number of buckets defined
owner name
Owner name string
alarm
number
number
This is the alarm index number of this entry (it is advisable to use
the same interface number as your alarm index number.)
the same interface number as your alarm index number.)
variable
This is the MIB variable which will be sampled by the alarm entry.
interval
The interval between 2 samples
sample
type
type
This can be set to either delta (the difference between 2 samples)
or an absolute value.
or an absolute value.
rising
threshold
threshold
This sets the upper threshold for the alarm entry.
rising
event
event
The RMON event entry that will be notified if the upper threshold
is passed.
is passed.
falling
threshold
threshold
This sets the lower threshold for the alarm entry.
falling
event
event
The RMON event entry that will be notified if the lower threshold is
passed.
passed.
startup
alarm
alarm
The instances in which the alarm will be activated. The possible
parameters are: Rising, Falling, risingOrfalling.
parameters are: Rising, Falling, risingOrfalling.