Microsoft ES4649 Manuale Utente

Pagina di 674
Stack Operations
2-5
2
the Master button is not depressed on any unit. The stack reboots and resumes 
operations. However, note that the IP address will be the same for any common 
VLANs (with active port connections) that appear in both of the new stack segments. 
To resolve the conflicting IP addresses, you should manually replace the failed link 
or unit as soon as possible. If you are using a wrap-around stack topology, a single 
point of failure in the stack will not cause the stack to fail. It would take two or more 
points of failure to break the stack apart.
Note: If a stack breaks apart, the IP address will be the same for any common VLANs 
(with active port connections) that appear in both stack segments.
Resilient IP Interface for Management Access 
The stack functions as one integral system for management and configuration 
purposes. You can therefore manage the stack through any IP interface configured 
on the stack. The Master unit does not even have to include an active port member 
in the VLAN interface used for management access. However, if the unit to which 
you normally connect for management access fails, and there are no active port 
members on the other units within this VLAN interface, then this IP address will no 
longer be available. To retain a constant IP address for management access across 
fail over events, you should include port members on several units within the primary 
VLAN used for stack management. 
Resilient Configuration
If a unit in the stack fails, the unit numbers will not change. This means that when 
you replace a unit in the stack, the original configuration for the failed unit will be 
restored to the replacement unit. This applies to both the Master and Slave units.
Renumbering the Stack
The startup configuration file maps configuration settings to each switch in the stack 
based on the unit identification number. If the units are no longer numbered 
sequentially after several topology changes or failures, you can reset the unit 
numbers using the “Renumbering” command in the web interface or CLI. Just 
remember to save the new configuration settings to a startup configuration file prior 
to powering off the stack Master.
Stack Limitations
Maximum Stack Size – You can stack up to eight units as long as total number of 
switch ASIC chips is less than 32. Both the ES4625 and ES4649 use one ASIC chip 
for each 12 ports and one ASIC for the optional module. If no optional modules are 
installed, then you can stack up to eight ES4625 or ES4649 units in any 
combination. However, if you install an optional module, then there will be three 
switch ASICs active in a ES4625 or five switch ASICs active in a ES4649. For 
example, if you build a stack of ES4649 switches with an optional module installed in 
each switch, then the maximum number of units that can be stacked together is six, 
because 30 switch ASICS will be active in a stack of this size.