Microsoft ES4649 Manuale Utente

Pagina di 674
Configuring the Switch
3-36
3
Web – Select SNTP, Configuration. Modify any of the required parameters, and click 
Apply.
Figure 3-23   SNTP Configuration
CLI – This example configures the switch to operate as an SNTP client and then 
displays the current time and settings.
Setting the Time Zone
SNTP uses Coordinated Universal Time (or UTC, formerly Greenwich Mean Time, 
or GMT) based on the time at the Earth’s prime meridian, zero degrees longitude. To 
display a time corresponding to your local time, you must indicate the number of 
hours and minutes your time zone is east (before) or west (after) of UTC.
Command Attributes
• Current Time – Displays the current time.
• Name – Assigns a name to the time zone. (Range: 1-29 characters)
• Hours (0-13) – The number of hours before/after UTC.
• Minutes (0-59) – The number of minutes before/after UTC.
• Direction – Configures the time zone to be before (east) or after (west) UTC.
Console(config)#sntp client
Console(config)#sntp poll 16
Console(config)#sntp server 10.1.0.19 137.82.140.80 128.250.36.2
Console(config)#exit
Console#show sntp
Current time:
Jan
6 14:56:05 2004
Poll interval: 60
Current
mode:
unicast
SNTP status : Enabled
SNTP server 10.1.0.19 137.82.140.80 128.250.36.2
Current server: 128.250.36.2
Console#