Allied Telesis AT-FS709FC Manuale Utente

Pagina di 46
4
Maximum Distance
The maximum distance of a twisted pair cable is 100 meters (328 feet). Cable 
lengths that exceed this limit can result in poor or erratic network 
performance.
Ports 1X to 7X — MDI-X Configuration
An RJ-45 twisted pair port on a 10 Mbps or 100 Mbps Ethernet network 
device can be wired as either MDI or MDI-X. Twisted pair ports on personal 
computers, routers, and bridges are typically wired as MDI. Twisted pair 
ports on switches and hubs are usually MDI-X. 
When connecting two network devices together, you need to use straight-
through twisted pair cabling when connecting two dissimilar ports together, 
such as an MDI port to an MDI-X port. To connect two similar ports together, 
such as an MDI port to an MDI port, you use a crossover twisted pair cable.
Ports 1X through 7X on the AT-FS709FC are configured as MDI-X. This 
means that if you are connecting a computer, router, or bridge to one of these 
ports, you probably need to use a straight-through twisted pair cable. 
If you decide to connect another Ethernet switch to one of these ports, or a 
hub, then you will probably need to use a crossover cable.
Port 8MDI and Port 8MDI-X
There are two Port 8s. One port is configured as MDI and the other as MDI-X. 
To connect a switch or hub to Port 8, connect it to Port 8MDI. When 
connecting a workstation or server to Port 8, use Port 8MDI-X.
Note
You can use either Port 8MDI or Port 8MDI-X. You cannot use both 
ports at the same time.