The MAC address table in the AT-FS709FC Series Ethernet switch can store 
up to 4,000 MAC addresses. To prevent the table from becoming filled with 
addresses of end nodes that are no longer active, the switch has a MAC 
address aging timer. This timer will delete a MAC address from the table if it 
does not see a frame from the end node with that address on any port after 
five minutes (300 seconds). The aging timer also helps to ensure that the table 
is correct should an end node be moved from one port on the switch to another 
port. 
Store and Forward
The Ethernet switch uses store and forward as the method for receiving and 
transmitting frames. When a Ethernet frame is received on a switch port, the 
switch does not retransmit the frame out the destination port until it has 
received the entire frame and stored the frame in its memory buffer. It then 
examines the frame to determine if it is a valid frame. Invalid frames, such as 
fragments, are discarded by the switch. In this manner, the switch ensures 
that only valid frames are transmitted out its ports and that damaged frames 
are not propagated on your network. 
Duplex Mode
Duplex mode determines the method by which an end node receives and 
transmits of data. If an end node can receive or transmit data, but not both at 
the same time, the end node is operating in what is referred to as half-duplex 
mode. If an end node can both receive and transmit data simultaneously, the 
node is operating in full-duplex mode. Naturally, a node capable of operating 
in full-duplex can handle data much faster than a node that can only operate 
in half-duplex.
Each twisted pair port on an AT-FS709FC Series switch can operate in either 
half- or full-duplex mode. The twisted pair ports are IEEE 802.3u-compliant 
and will Auto-negotiate the duplex mode setting. If the end node connected to 
a twisted pair port on the switch is capable of full-duplex operation, the switch 
sets the twisted pair port to full-duplex. If the end node is capable of only half-
duplex, the port is set automatically to half-duplex.
The duplex mode for the fiber optic port is set to full-duplex. This cannot be 
changed. The end node that you connect to the fiber optic port must be capable 
of full-duplex operation.