Allied Telesis AT-FS709FC Manuale Utente

Pagina di 46
AT-FS709FC Series Installation Guide
21
G Make sure that the cable connected to the fiber optic receiver port on 
the switch is connected to the transmitter port on the remote end node 
and that the fiber optic transmitter port on the switch is connected to 
the receiver port on the end node.
G Test the attenuation on the fiber cable to ensure that it does not 
exceed acceptable values. 
G Verify that you are using the appropriate type of fiber optic cabling 
and that you have not exceeded the allowable maximum distance. For 
information, refer to “Twisted Pair Cable and Fiber Optic Cable 
Guidelines” on page 17.
G Check that the operating specifications (e.g., wavelength and 
maximum operating distance) of the fiber optic port on the end node 
are compatible with the operating specifications of the fiber optic port 
on the Ethernet switch.
G Verify that the end node connected to the fiber optic port is operating 
in full-duplex mode.
Note
See “Technical Specifications” on page 21 for the operating 
specifications of the fiber optic port on the switch.
Warranty Registration
When you have finished installing the switch, register your product by 
completing the enclosed warranty card and sending it in, or by visiting our 
web site at www.alliedtelesyn.com/support/warrantyf.asp and 
completing the on-line registration.
Technical Specifications
Table 6 lists the switch specifications.
Table 2  Technical Specifications
Physical Specifications
Dimensions (H x W x D)
4.4 cm x 33.0 cm x 20.3 cm
(1.7 in x 13 in x 8.0 in)
Weight
2.0 kg (4.0 lbs)
Required Ventilation (all sides)
19 cm (7.5 in)