Elmo Tuba Digital Servo Manuale Utente

Pagina di 74
3.4.2 
Connecting the Power Cables 
Access the power terminal connections on the Tuba servo drive by removing the front safety 
cover located at the bottom of the front panel of the unit, as shown below: 
 
Figure  3-6: Removable Bottom Panel 
After removing the safety cover, the power terminal connections are visible, as follows:  
 
Figure 
 
3-7: Tuba Power Connectors 
The main power connector located at the bottom of the Tuba, as follows:  
Pin Function 
Cable 
Pin 
Positions 
B1 
DC Link (+) 
DC Link 
B2 
DC Link (-) 
DC Link 
AC3 Phase 
Power 
AC2 Phase 
Power 
AC1 Phase 
Power 
PE Protective 
earth 
Power 
 
 
AC Motor
Cable 
DC Motor
Cable 
PE Protective 
earth Motor  Motor 
M3 Motor 
phase 
Motor 
N/C* 
M2 Motor 
phase 
Motor 
Motor 
M1 Motor 
phase 
Motor  Motor* 
 
When connecting several motors, all must be wired in an identical manner. 
On prototype versions of the Tuba, M3 was connected to the Motor and M1 was not. 
Table  3-2: Connector for Main Power and Motor Cables 
Tuba Installation Guide 
 Installation 
MAN-TUBIG (Ver. 1.3) 
 
3-10