Elmo Tuba Digital Servo Manuale Utente

Pagina di 74
A.5 Power 
Ratings 
Feature 
Units 
12/230 15/230 20/230 12/460 15/460 20/460 
Minimum supply voltage 
VAC 
60 
140 
Nominal supply voltage 
VAC 
1 x 115, 1 x 230, 3 x 230 
3 x 400, 3 x 460 
Maximum supply voltage 
VAC 
1 x 270 or 3 x 270 
3 x 505 
Maximum continuous 
power output 
W 3600 4500 6000  6800  8500  11300 
Efficiency at rated power 
(at nominal conditions) 
% > 
93 
Auxiliary supply voltage  
VDC 
24 ± 15% 
Auxiliary power supply  
VA 
20 
Amplitude sinusoidal/DC 
continuous current 
12 15 20 12 15 20 
Sinusoidal continuous RMS 
current limit (Ic) 
A 8.5 10.6 14.1  8.5  10.6 14.1 
Peak current limit
 
2 x Ic 
Built-in shunt (peak power) 
kW 
11 
Weight 
kg 
(lbs) 
2.7 kg (5.9 lbs) 
Dimensions 
mm 
(in) 
247 x 190 x 92 (9.7" x 7.5" x 3.6") 
Digital in/Digital 
out/Analog in 
 10/6/2 
Mounting method 
 
Wall mount (“Bookshelf”) or DIN rail 
 
A.6 Environmental 
Conditions 
Feature Details 
Ambient operating temperature 
0 °C – 40 °C (32 °F – 104 °F) 
Storage temperature 
-20° ~ +85° C ( -4° ~ +185° F) 
Maximum humidity 
90% non-condensing  
Protection level 
IP20 
Tuba Installation Guide 
Technical Specifications 
MAN-TUBIG (Ver. 1.3)
 
 
A-5