Elmo Tuba Digital Servo Manuale Utente
A.5 Power
Ratings
Feature
Units
12/230 15/230 20/230 12/460 15/460 20/460
Minimum supply voltage
VAC
60
140
Nominal supply voltage
VAC
1 x 115, 1 x 230, 3 x 230
3 x 400, 3 x 460
Maximum supply voltage
VAC
1 x 270 or 3 x 270
3 x 505
Maximum continuous
power output
power output
W 3600 4500 6000 6800 8500 11300
Efficiency at rated power
(at nominal conditions)
(at nominal conditions)
% >
93
Auxiliary supply voltage
VDC
24 ± 15%
Auxiliary power supply
VA
20
Amplitude sinusoidal/DC
continuous current
continuous current
A
12 15 20 12 15 20
Sinusoidal continuous RMS
current limit (Ic)
current limit (Ic)
A 8.5 10.6 14.1 8.5 10.6 14.1
Peak current limit
A
2 x Ic
Built-in shunt (peak power)
kW
6
11
Weight
kg
(lbs)
2.7 kg (5.9 lbs)
Dimensions
mm
(in)
247 x 190 x 92 (9.7" x 7.5" x 3.6")
Digital in/Digital
out/Analog in
out/Analog in
10/6/2
Mounting method
Wall mount (“Bookshelf”) or DIN rail
A.6 Environmental
Conditions
Feature Details
Ambient operating temperature
0 °C – 40 °C (32 °F – 104 °F)
Storage temperature
-20° ~ +85° C ( -4° ~ +185° F)
Maximum humidity
90% non-condensing
Protection level
IP20
Tuba Installation Guide
Technical Specifications
MAN-TUBIG (Ver. 1.3)