Dell PowerEdge 6350 Systems Service Manual
6(&&DUWULGJHDQG+HDW6LQN$VVHPEO\
To remove a single-edge contact (SEC) cartridge and heat sink assembly, fol-
low these steps.
:$51,1* 7KH 6(& FDUWULGJH DQG KHDW VLQN DVVHPEO\ FDQ JHW
H[WUHPHO\ KRW GXULQJ V\VWHP RSHUDWLRQV %H VXUH WKDW LW KDV KDG
VXIILFLHQW WLPH WR FRRO EHIRUH WRXFKLQJ LW
:$51,1* :KHQ KDQGOLQJ WKH 6(& FDUWULGJH DQG KHDW VLQN DVVHP
EO\ WDNH FDUH WR DYRLG VKDUS HGJHV RQ WKH KHDW VLQN
1.
For the unit to be removed, press outward on the two SEC cartridge 
release latches until they snap into the open position (see Figure 4-18).
)LJXUH  6(& &DUWULGJH 5HOHDVH /DWFKHV
2. Grasp the heat sink and pull the SEC cartridge/heat sink assembly straight 
up out of the connector and guide bracket assembly (some force may be 
required).
To replace an SEC cartridge, make sure the cartridge release latches are in the 
open position, orient the new SEC cartridge in the guide bracket assembly as 
shown in Figure 4-18, seat it firmly, and then snap the release latches back into 
place.
To install an SEC cartridge where there was none before, you will need
to remove the installed terminator cartridge (see the next subsection,
“Terminator Cartridge”).
heat sink
SEC cartridge
guide bracket 
assembly
release latches (2)