Lightwave Communications 3200 Manuale Utente

Pagina di 88
 
31
 
sys admin>>NETWORK B 
Enter accepts present value 
N-B: Enter IP address               | 000.000.000.000> 172.16.1.1 
N-B: Enter Subnet Mask              | 255.255.255.255> 255.255.255.0 
N-B: Enter Default Gateway address  | 255.255.255.255> 172.16.1.200 
N-B: Enter 2nd Dest. Network        | 255.255.255.255> 
N-B: Enter 2nd Netmask              | 255.255.255.255> 
N-B: Enter 2nd Gateway address      | 255.255.255.255> 
N-B: BOOTP at startup?              | Y> 
Save changes and update card? Yes or No: No>y 
Card installed, settings updated 
 
sys admin>> 
 
 
When the NETWORK command is used with a card slot letter as a command qualifier, it 
will attempt to change the parameters only for that card slot.  In all other aspects, the 
command behaves the same as if the /ALL qualifier was used. 
 
If a bootp server is present on the same network as the ConsoleServer 3200 network 
card and bootp is enabled on the network card, then the network card will use the IP 
address and subnet mask assigned by the bootp server rather than those assigned by 
the sys admin.  
 
Once a network card has been assigned an IP address either by a bootp server or by 
the sys admin, then the ConsoleServer may be accessed by telnet.  Connecting to the 
default telnet port reaches the user login; connecting to port 5000 reaches the sys 
admin login. 
 
6.6 
Modem
Modem
Modem
Modem Command 
 
The MODEM command allows manipulation of the modem card initialization string.  When 
the command is entered, the sys admin is prompted for the new initialization string.  
Typing a new initialization string and pressing <ENTER> will create a new initialization 
string for the modem, while just pressing <ENTER> will accept the current value.  After 
pressing <ENTER>, the sys admin is asked to confirm the changes to send the string to 
the modem.  Typing YES and <ENTER> will send the initialization string immediately to 
the modem card, while typing NO and <ENTER> discards the entered initialization string 
and keeps the old string.  If the modem card is not currently installed, the settings are 
not sent, but are kept in control card memory.  The control card will send those settings 
in memory when a modem card is installed.