Open the retention clips on both sides of the slot and insert the memory 
module. 
Align a notch of the memory module to correspond with the memory slot and insert the module 
perpendicularly to the slot.
When the module is correctly inserted, the retention clips on both sides will close. Then, check 
that they secure the memory module.
If the retention clips are not securely closed, push them with your fingers to close. 
7
Attach the ventilation system cover. 
To attach it, simply reverse the removal procedures. 
8
Attach the side cover.
9
Turn on the server and start the BIOS Setup Utility. Initialize the Extended 
System Configuration Data (ESCD) area.
1. Start the BIOS Setup Utility and set [Reset Configuration Data] on the [Advanced] 
menu to [Yes].
2. From the [Exit] menu, select [Save Changes & Exit] and press the [Enter] key.
10
Store the BIOS settings.
• An improperly engaged memory module could cause a fire. Do not
insert the memory module on the wrong side. 
Align notch