CHAPTER 10 Error Notification and Maintenance (Contents, Methods, and Procedures) 
10.4 Collecting Maintenance Data 
188 
 
C122-E175-01EN 
 
FIGURE 10.14 [System Event Log Filtering Condition] window in PRIMEQUEST 2800B 
 
 
2.  Specify the condition to filter events. Then, click the [Apply] button. 
The [System Event Log] window appears again. The window displays the events matching the specified 
conditions. 
To clear the specified conditions and return to the [System Event Log] window, click the [Cancel] button. 
To clear the specified conditions and restore the default values, click the [Default Setting] button. 
TABLE 10.5 Setting and display items in the [System Event Log Filtering Condition] window 
Item 
Description 
Severity 
Select the severity of events to display by using the following check boxes. 
You can check multiple check boxes. 
- Error 
- Warning 
- Info 
All check boxes are checked by default. 
Partition (*1) 
Select the partition to display. 
Select the [All] or [Specified] radio button. 
If you select [All], filtering by partition will not be applied. In this case, the 
check boxes for partitions in [Specified] are grayed out and cannot be 
checked. 
If you select [Specified], you can check the check boxes for selecting a 
partition. 
Even after a switch to [All] and back to [Specified], the window retains the 
selections made with the [Specified] check boxes 
[All] is grayed out and cannot be selected for users with Partition Operator 
accounts. Also, they can select partition filtering only for the target partition. 
The default settings are as follows: 
- For other than Partition Operator, [All] radio button. 
- For Partition Operator, [Specified] radio button and target partition. 
Unit 
Select the units to display. 
Select the [All] or [Specified] radio button. 
If you select [All], filtering by unit is not applied. 
If you select [Specified], you can set filtering by unit. Check the check box of a 
unit to display the events of that unit. 
Even after a switch to [All] and back to [Specified], the window retains the 
selections made with the [Specified] check boxes.