Fujitsu N800 Manuale Utente
![Fujitsu](https://files.manualsbrain.com/attachments/6c4642b33d2edbd09f94719c20a133aa0e862902/common/fit/150/50/80a45702a21fefb1823bce6851e87db450dccf7792cb572ebc8a90330a68/brand_logo.png)
U41243-J-Z156-1-76
9
Introduction
Technical data
1.6
Technical data
Electrical data
Rated voltage range
100 V - 120 V
200 V - 240 V (auto sense)
200 V - 240 V (auto sense)
Rated voltage tolerance
+6 % / -10 %
Frequency
50 Hz / 60 Hz
Rated current at 100V - 120 V
12 A
Rated current at 200V - 240 V
7 A
Effective power
1247 W
Apparent power
1271 VA
Heat emission
4014 kJh
Building fuse
16 A
Protection class
I
Dimensions and weight
Height (mm)
312 (seven height units)
Width (mm)
445
Depth (mm)
712
Weight (kg)
max. 60 (maximum configuration)
Environmental conditions (according to DIN EN 60721-3-x)
Operating climate (Class 3K2):
Temperature (°C)
10 to 35
Relative humidity(%)
5 to 85
Environmental conditions/transport (Class 2K2):
Temperature (°C)
-25 to 60
Relative humidity (%)
15 to 98
Mechanical environmental conditions
Operation
Class 3M2
Transport
Class 2M2