Lucent Technologies lucent Manuale Utente

Pagina di 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-632
EXP-INTF (Expansion Interface Circuit Pack) 
10
Expansion Interface Reset Test (#336)
This test is potentially very destructive and requires the Expansion Interface 
circuit pack to be busied out prior to execution of this test.
The Expansion Interface Reset Test, which is not a part of either the Short or the 
Long Test Sequences, is executed via the 
reset board PCSS
 command where 
PCSS is the address of the Expansion Interface circuit pack to be reset.
If the system only has one working Expansion Interface Link between a pair of 
port networks and one of the Expansion Interface circuit packs must be reset, the 
FAIL
The Expansion Interface circuit pack responded incorrectly or, if it is the EPN 
Active Expansion Interface circuit pack, it could not talk to EPN circuit packs.
1. If the Active Expansion Interface circuit pack in the EPN is failing and a 
Standby link exists, switch to the Standby link using the 
set 
expansion-link PCSS
 command.
2. Repeat the Short Test Sequence.
3. If test continues to fail, reset the Expansion Interface circuit pack via the 
reset board PCSS
 command.
4. If the Expansion Interface circuit pack in the EPN is failing, check for EPN 
TDM-CLK, TONE-BD, or SYNC failures in the Hardware Error Log. Clear 
any EPN clock-related failures and repeat the Short Test Sequence.
5. If test continues to fail, replace the circuit pack or transceiver.
PASS
The Expansion Interface circuit pack did respond correctly to the test. 
Communication from software to the Expansion Interface circuit pack is 
functioning.
1. Refer to other Expansion Interface circuit pack tests if Expansion Interface 
Link is not functioning correctly.
0
NO 
BOARD
No board was detected by the test.
1. Check the error log for wrong board (error 125) or no board (error 131). 
Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check for 
hyperactivity (error 1538). If hyperactive, use the 
reset board PCSS 
command.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace the 
board and retest.
Table 10-214.
TEST #316 Expansion Interface 
Control Channel Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page