Raritan Computer Server Manuale Utente

Pagina di 3
 
Dominion SX Quick And Installation Guide 
3
  y 255-60-2010-00 
 
3.  When the Login prompt appears, enter the default 
username (admin) and password (raritan). Use all 
lowercase letters. 
4.  You will be prompted to change the default password. Do 
so now, and be sure to remember this password for future 
login. 
5.  At the admin > prompt, enter config, and at the next 
prompt, enter network. 
6.  Give the Dominion SX an IP address, subnet mask, and 
gateway address on your LAN. At the admin > config > 
network > prompt, enter: interface enable true if 
lan1 ip <ip address> mask <subnet mask> gw 
<gateway ip address>
 
7.  You will now be prompted to reboot the Dominion SX. 
Enter yes to start the reboot. When it is complete, log in 
again using your new password. 
8.  Give the unit a name to help identify it (up to 64 
characters, spaces and special characters not ( allowed) 
and your domain (required to send SMTP messages). 
Enter: name unitname <DSX name> domain <domain 
name> 
9.  You will now be prompted to reboot the Dominion SX. 
Enter yes to start the reboot. When it is complete, log in 
again. 
10. At the admin > prompt, enter config, and at the next 
prompt, enter time. 
11. At the admin > config > time > prompt, set the date and 
time on the Dominion SX. 
a.  Enter timezonelist and find the number code that 
corresponds to your time zone. 
b.  Enter: clock tz <timezone code> datetime <"time 
string"> where <timezone code> is the time zone code 
and <”time string”> is the current date and time in 
“YYYY-MM-DD HH:MM:SS" format (quotes included, 
use 24-hour time). Example: clock tz 9 datetime 
“2007-03-15 09:22:33” 
12. Enter top to return to the top level prompt. Then, enter 
config, and at the next prompt, enter ports. You can now 
configure each console port that has a target device 
connected to it: 
a.  Enter: config port <port number> followed by the 
parameters described in the table below. Example
config port 1 name cisco1700 bps 9600 parity odd 
flowcontrol none emulation vt100 
Note: In addition to the parameters above, additional 
parameters include: [detect <true|false>] [escapemode 
<none|control>] [ escapechar char] [emulation type] 
[exitstring <cmd[#delay;]>] [dpaip ipaddress] [telnet port] 
[ssh port] [alwaysactive <true|false>] [suppress 
<none|all>] 
b.  Repeat Step a for each port with a device connected to 
it. 
Note: You can also use port ranges or the wildcard 
asterisk *, as in: config port * bps 115200. This will 
configure all ports for a communications speed of 115200 
bps. Or: config port 3-7 bps 115200. This will configure 
ports 3 through 7 for 115200 bps. Or: config port 1,2,7-9 
bps 115200. This will configure ports 1, 2, 7 trough 9 for 
115200 bps. 
13. When done, enter top to return to the top level prompt. 
Congratulations! Your Dominion SX is configured and ready 
for use. 
 
QS Rule 
 
Additional Information 
For more information about the Dominion SX and the entire 
Raritan product line, refer to the Raritan User Guide & Quick 
Setup Guides CD ROM or Raritan's website 
http://www.raritan.com/support. For technical issues, contact 
Raritan Technical Support by telephone (732) 764-8886, fax 
(732) 764-8887, or email tech@raritan.com, Monday - Friday 
8:00 AM to 8:00 PM EST.