7.2.3 
Serial Login/Logout 
To monitor serial ports and check for login/logout or pattern matches for Auto-Response triggers events:  
  Click on Serial Login/Logout as the Check Condition. Then in the Serial Login/Logout 
Check menu select Trigger on Login (to trigger when any user logs into the serial port) or 
Trigger on Logout and specify  Serial Port to perform check on, and/or 
  Click on Serial Signal as the Check Condition. Then in the Serial Signal Check menu 
select the Signal (CTS, DCD, DSR) to trigger on, the Trigger condition (either on serial 
signal change, or  check level) and specify  Serial Port to perform check on, and/or  
  Click on Serial Pattern as the Check Condition. Then in the Serial Pattern Check menu 
select the PCRE pattern to trigger on and the serial line (TX or  RX) and Serial Port to 
pattern check on  
  Check Save Auto-Response 
Note:    Before configuring serial port checks in Auto-Response you first must configure the serial port in 
Console server mode. Also most serial port checks are not resolvable so resolve actions will not 
be run 
7.2.4 
ICMP Ping 
To use a ping result as the Auto-Response trigger event:  
  Click on ICMP Ping as the Check Condition  
  Specify which Address to Ping (i.e. IP address or DNS name to send ICMP Ping to) and 
which Interface to send ICMP Ping from (e.g. Management LAN or Wireless network) 
  Set the Check Frequency (i.e. the time in seconds between checks) and the Number of 
ICMP Ping packets to send  
  Check Save Auto-Response 
 
7.2.5 
Cellular Data 
This check monitors the aggregate data traffic inbound and outbound through the cellular modem as an 
Auto-Response trigger event. 
  Click on Cellular Data as the Check Condition 
Note:    Before configuring cellular data checks in Auto-Response the internal or external USB cellular 
modem must be configured and detected by the console server 
7.2.6 
Custom Check  
This check allows users to run a nominated custom script with nominated arguments whose return value 
is used as an Auto-Response trigger event:  